The Mercedes- Benz New Vito Advanced Negative Pressure Monitoring and Transfer Medical Vehicle combines superior design, strong power and outstanding maneuverability. The vehicle is equipped with a 2.0T gasoline engine, a 9-speed automatic transmission, and a dual-clutch. The active and passive safety configuration of cutting-edge technology fully guarantees travel safety and work efficiency. Combining the highest safety standards and advanced ambulance equipment , the new Vito Advanced Negative Pressure Monitoring and Transfer Medical Vehicle has optimized space for rescue operations in the vehicle, and its flexible handling performance is more suitable for driving on narrow roads in the city, providing patients with Quick transfer, increase golden rescue time , and achieve complete medical services such as excellent medical rescue quality and nursing services.
Main technical parameters and configuration of the vehicle
size and quality
Wheelbase mm: | 3430 |
Body size mm: | 5370x1928x2360 (LxWxH) |
Medical cabin size mm: | 2700x1670x1700-1750 (LxWxH) |
Vehicle curb weight kg: | 2480 |
Full load total mass kg: | 3100 |
engine | |
Type of fuel: | gasoline |
Way of working: | M274 gasoline engine turbocharged direct injection |
Exhaust volume cm: | 1991(2.0T) |
Emission Standards: | Emission standard: GB18352.6-2016 National VI |
Maximum power kw/rpm: | 155/5500 |
Maximum torque Nm/rpm: | 350/1250-4000 |
Braking System | disc brake |
transmission: | |
Automatic Transmission | 9-speed automatic transmission |
Top speed km/h: | 185 |
tire: | 235/55R17 tires, 17-inch five-spoke alloy wheels |
Vehicle standard configuration | |
ECO engine start/stop function | |
Dynamic driving mode selection (Economy/Comfort/Manual) | |
Electromechanical power steering | |
Electronic Stability System (ESP) | |
Anti-lock Braking System (ABS) | |
Electronic Anti-Slip System (ASR) | |
Brake force distribution system (EBD) | |
Brake Assist System (BAS) | |
Brake Disc Wiping (BDW) | |
Electronic Preheating (EBP) | |
High Speed Steering Brake Control (CBC) | |
Load Applicable Control (LAC) | |
hill start assist | |
cruise control | |
Cab with two seats | |
Driver and passenger dual airbags | |
three-point seat belt | |
Driver's seat belt not fastened reminder | |
Parameterizable Special Purpose Module (PSM) |
,,, Lift-up rear door, hydraulic strut |
Air conditioning and lighting systems |
Cab installation air conditioner |
The medical cabin is equipped with the original air conditioner and heater |
Two-way exhaust system installed on the roof of the medical cabin |
Ambulance outfield lights and high-mounted brake lights are installed at the rear of the roof |
Medical cabin top ring LED lighting |
Two rotatable surgical spotlights and one circular UV disinfection lamp are installed on the top of the medical cabin |
The medical cabin lighting system can effectively meet the needs of medical staff to treat patients in the cabin |
Power Systems |
The battery is installed under the passenger seat and all its connections prevent the possibility of a short circuit under any circumstances |
Cab installation power overload protection device and electrical centralized controller |
When the vehicle is started, it can realize 24-hour uninterrupted power supply, can output 220V, not less than 1000W power frequency pure sine wave inverter |
Power supply available for medical equipment |
10m long mobile cable |
Install 4 220v sockets in the medical cabin |
Two 12v sockets are installed in the medical cabin |
220V/16A waterproof, external power socket with protective cover |
emergency alert system |
Cab-mounted alarm, warning light control handle |
The vehicle is equipped with dual electric horns, sirens, microphones, and alarms with slow-speed dual-tone conversion tones, in line with the relevant regulations of the Ministry of Public Security |
External loudspeaker built into siren |
Long strip flashing warning lights (blue) installed at the front of the roof |
There are 2 blue strobe lights, 1 off-field lighting and 2 high-mounted brake lights on the left and right sides of the roof tail. |
Medical cabin equipment |
The interior of the medical cabin adopts the overall one-time mold forming process of ABS material, which has the characteristics of high surface hardness, smooth, antibacterial, easy to clean, |
Disinfection, anti-aging and other functions |
A 7-inch high-definition touch LCD screen and emergency manual switch are installed on the right front of the medical cabin. The attached screen of the waterproof membrane switch is located in the left rear oxygen cabinet. |
superior |
A partition wall is installed between the cab and the medical cabin. The partition wall can completely separate the cockpit and the first aid cabin. The one-time mold of ABS material is used. |
forming process. The partition wall is equipped with a movable transparent sliding window of not less than 0.2 square meters, and the sliding window glass has a locking device. |
There is a scoop stretcher compartment behind the dividing wall of the medical compartment, and a folding seat with a safety belt is installed on the right side |
A long seat and a forward-facing doctor seat are installed on the right side of the medical cabin. The long seat adopts a one-time molding process of ABS material. |
Two people can sit at the same time (with seat belts and backrests), the space on both sides under the seat cushion can be used as a toolbox, and the middle door guide rail is reserved above the cabinet bed. |
Repair holes. The seat cushion of the cabinet bed should adopt a one-time mold forming process, and there should be no stitching seams on the surface, and it is easy to wash and disinfect. |
The integrated inner roof on the top of the medical cabin integrates lighting, storage, ventilation, sterilization, infusion stand, all-round |
Ring armrest and other functions |
The upper left side of the medical cabin is designed with a double-layer storage wall cabinet. |
A set of medical equipment cabinets and operating platforms are installed on the left side of the medical cabin |
There is an electrical column in the middle of the left side of the medical cabin, which can be installed with oxygen sockets for ventilators and humidification bottles. |
There is a completely closed oxygen supply system in the medical cabin |
Bulletproof configuration:
B6 can accept M80 Ball pistols, AK-47s, assault rifles, M-16 rifles and NATO 7.62cm standard rifles without being pierced.
1 Vehicle spraying bulletproof material, bulletproof glass (interior customization)
2 The vehicle is sprayed with bulletproof materials, the interior is decorated with lightweight bulletproof panels, and bulletproof glass (interior customization)
Bulletproof vehicle customization process and design
Dismantling and protection of the first vehicle: After dismantling all instrument panels, electrical and electronic equipment, car safety devices, seats, interiors, floors, roofs, and safekeeping, protect the body surface
Second: the production and installation of body anti-fixation: implement bulletproof and anti-riot protection for all parts of the A, B, C pillars, roof, and bottom around the body, strengthen the door pillars and door hinges of all doors, Double-layer protection is implemented for the part where the structure is handed over; the water tank, battery, and central control ECU are protected; the mailbox is protected against riots, and the tires are changed to bulletproof tires.
Third: Improvement and strengthening of chassis performance: According to the comprehensive performance of the chassis after modification with different protection levels, the suspension system, braking system and power system are improved
Fourth: Add interiors and various equipment of the original car: Perfectly restore the interior of the passenger car, complete the interior production for medium and heavy bulletproof vehicles, and strive to be practical, authentic and safe. All electrical and electronic equipment of the original car, Restoration of car safety devices
Fifth: Installation of optional configuration: installation of various optional configurations such as vehicle monitoring system, fire extinguishing system, etc.
Sixth: Vehicle performance test: Test the driving performance, lighting, auxiliary functions and equipment performance of the modified bulletproof vehicle one by one
Seventh: User driving training: professionally train customers how to drive a bulletproof car after gaining weight, teach customers how to drive a bulletproof car in different environments, and teach customers how to deal with and avoid attacks correctly when they encounter an attack
There is a cabinet at the left rear of the medical cabin that can hold two 10L oxygen cylinders
The floor of the medical cabin is made of wear-resistant, acid-resistant, alkali-resistant, flame-retardant, non-slip, mildew-proof, and easy-to-clean medical-specific plastic floors.
Negative pressure device
1. Function: The function of the negative pressure system enables the medical cabin to form an atmospheric low pressure difference relative to the external environment, and through the exhaust device and the connected high-efficiency filter sterilizer, it prevents the leakage of polluted air in the medical cabin, and achieves The purpose of ventilation and not polluting the environment.
2. Relative pressure: When starting the negative pressure device, the relative pressure in the cabin is -30Pa ~ -10Pa.
3. Filter efficiency: the filtration rate of the air filter for particulate aerosols with a particle size of 0.3 μm is greater than 99.998%.
4. Structure and composition: The air purification system consists of air inlet, purification and exhaust device, control and monitoring device. The purification and exhaust device is composed of exhaust fan, air filter and sterilizer. The air filter and sterilizer should be installed at the suction port of the purification and exhaust device. The air inlet and outlet are basically arranged in accordance with the diagonal principle of upper in and lower row, forward and rear out , and the control device is placed in the medical cabin and cab for easy operation and control.
5. The high-efficiency negative pressure device is composed of imported fan, activated carbon filter layer, high-efficiency filter layer, and ultraviolet disinfection device.
6. The fan is imported from Germany, and the negative pressure effect can reach -10 to -30Pa (the current standard of the Ministry of Health is -10 to -30Pa);
7. The filter device is a double-layer professional filter layer, which is divided into an activated carbon filter layer and a high-efficiency filter layer. The activated carbon filter layer can effectively absorb harmful substances and odors. improve security;